S20 Series 10 kV Oil-Immersed Transformer
Product Overview
S(B)20-M Series
Product Overview
S20 Series three-phase oil-Immersed transformers as the next-generation energy-efficient power equipment, it achieves a breakthrough in energy efficiency with 30% lower no-load losses and 25% reduced load losses compared to the S13 series. Featuring a core constructed from high-permeability grain-oriented silicon steel laminations with stepped-lap joints, the design minimizes hysteresis and eddy current losses, resulting in a 40% reduction in no-load current.
The fully sealed corrugated tank design automatically compensates for oil volume fluctuations caused by temperature changes through elastic deformation of the corrugated sheets. This hermetic structure eliminates the need for an oil conservator, enabling maintenance-free operation and extending service life to over 35 years.
Share the model, quantity, drawing, destination and project requirement for a focused response.
Model Definition

Features
Range of application
Technical specifications
|
Rated capacity |
Rated voltage |
Vector group |
No-load loss (W) |
Load loss (W) |
No-load current |
Impedance voltage |
||||||||||
|
HV |
Tapping range (%) |
LV |
11# |
13# |
20# |
22# |
11/13# |
20# |
22# |
11# |
13# |
20# |
22# |
|||
|
30 |
6 |
±5 or ±2×2.5 |
0.4 |
Dyn11 or Yyn0 |
100 |
80 |
70 |
65 |
630/600 |
505/480 |
455/430 |
0.3 |
0.3 |
0.24 |
0.23 |
4 |
|
50 |
130 |
100 |
90 |
80 |
910/870 |
730/695 |
655/625 |
0.24 |
0.23 |
0.24 |
0.23 |
|||||
|
80 |
180 |
130 |
115 |
105 |
1310/1250 |
1050/1000 |
945/900 |
0.22 |
0.18 |
0.21 |
0.20 |
|||||
|
100 |
200 |
150 |
135 |
120 |
1580/1500 |
1265/1200 |
1140/1080 |
0.21 |
0.16 |
0.21 |
0.20 |
|||||
|
125 |
240 |
170 |
150 |
135 |
1890/1800 |
1510/1440 |
1360/1295 |
0.2 |
0.15 |
0.19 |
0.18 |
|||||
|
160 |
280 |
200 |
180 |
160 |
2310/2200 |
1850/1760 |
1665/1585 |
0.19 |
0.14 |
0.18 |
0.17 |
|||||
|
200 |
340 |
240 |
215 |
190 |
2730/2600 |
2185/2080 |
1970/1870 |
0.18 |
0.12 |
017 |
0.16 |
|||||
|
250 |
400 |
290 |
260 |
230 |
3200/3050 |
2560/2440 |
2300/2195 |
0.16 |
0.12 |
0.14 |
0.13 |
|||||
|
315 |
480 |
340 |
305 |
270 |
3830/3650 |
3065/2920 |
2760/2630 |
0.16 |
0.11 |
0.13 |
0.12 |
|||||
|
400 |
570 |
410 |
370 |
330 |
4520/4300 |
3615/3440 |
3250/3095 |
0.16 |
0.11 |
0.13 |
0.12 |
|||||
|
500 |
680 |
480 |
430 |
385 |
5410/5150 |
4330/4120 |
3900/3710 |
0.16 |
0.1 |
0.12 |
0.11 |
|||||
|
630 |
810 |
570 |
510 |
460 |
6200 |
4960 |
4460 |
0.15 |
0.09 |
0.12 |
0.11 |
4.5 |
||||
|
800 |
980 |
700 |
630 |
560 |
7500 |
6000 |
5400 |
0.15 |
0.09 |
0.1 |
0.1 |
|||||
|
1000 |
1150 |
830 |
745 |
665 |
10300 |
8240 |
7415 |
0.14 |
0.09 |
0.1 |
0.09 |
|||||
|
1250 |
1360 |
970 |
870 |
780 |
12000 |
9600 |
8640 |
0.13 |
0.08 |
0.1 |
0.09 |
|||||
|
1600 |
1640 |
1170 |
1050 |
940 |
14500 |
11600 |
10440 |
0.12 |
0.07 |
0.09 |
0.08 |
|||||
|
2000 |
1940 |
1360 |
1225 |
1085 |
18300 |
14640 |
13180 |
0.11 |
0.09 |
0.09 |
0.08 |
5.5 |
||||
|
2500 |
2290 |
1600 |
1440 |
1280 |
21200 |
14840 |
13360 |
0.11 |
0.08 |
0.09 |
0.08 |
|||||
|
3150 |
2750 |
2180 |
24100 |
0.11 |
0.08 |
6 |
||||||||||
Oil-Immersed Transformer Components
Reference component and partner-factory production images. Components, conservator and breather availability depend on the selected design.
Test Control Panel
Steel control panel operating routine-test circuits (ratio, insulation resistance, dielectric) for safe, standard-compliant testing.
Flange Connection
High-strength bolted flange with machined sealing face and oil-resistant gasket — a leak-free oil path for the long run, and easy to open when service is needed.
Finished Porcelain Bushings
Multi-shed porcelain bushings increase creepage distance to cope with outdoor dust and rain.
Transformer Core and Clamp Structure
Painted steel clamps and tie rods hold the laminations tight to cut noise, with single-point core earthing to prevent floating discharge.
Heat Dissipation Panel
Pressed or welded steel fins, phosphated and powder-coated, enlarge the radiating surface and release heat by natural oil convection.
Silica Gel Breather
The silica gel breather is installed at the end of the conservator breathing pipe. The color-indicating silica gel inside appears blue/purple when dry and turns pink once saturated, allowing a quick visual check for replacement. As the oil volume expands and contracts, the breather continuously filters the air entering the conservator and prevents moisture from reaching the transformer oil — a key component for maintaining insulation performance. The oil cup at the bottom allows oil-level observation and dust separation.
Oil-Immersed Transformer Production Line
Reference image from the partner factory. Standardized line covering assembly, drying, oil filling and painting ensures batch consistency and short lead times for export orders.
10 kV Distribution Transformer Testing Area
Reference image from the partner factory. Finished S11/S13/M units are tested one by one before dispatch, verifying electrical and insulation performance with test reports supplied.
Oil-Immersed Transformer Applications
Typical application scenarios. The installations shown are examples; voltage, capacity and mounting arrangement require project-specific confirmation.
Pole-Mounted Transformer: Rural Supply
Where used: Serves scattered rural loads such as village supply and irrigation wells — pole-mounted for minimal land use, fast installation and low cost.
Outdoor Substation: Regional Grid
Where used: Main-transformer bays of 35–110 kV substations, stepping down and distributing power to cities, towns and industrial load centers.
Solar Power Station: Grid Connection
Where used: Steps up PV inverter output to 10/35 kV for grid connection, coping with strong UV, wide temperature swings and day-full / night-light duty.
Industrial Park: Factory Supply
Where used: Supplies industrial parks, plants and mine processing facilities — production lines, large motors and compressors — with dust-resistant, continuous heavy-load capability.
Inquiry Now
Send the model, drawing, BOM or project specification. Our team will respond around the actual selection points.
Open Full Enquiry Page