IEEE Normal Duty Surge Arrester
IEEE overvoltage load surge arresters are suitable for outdoor AC 48-62Hz and meet the requirements of power distribution systems of different voltage levels under IEEE standards.
Share the model, quantity, drawing, destination and project requirement for a focused response.
Product Overview
IEEE overvoltage load surge arresters are connected in parallel with the protected electrical equipment to limit lightning overvoltages, switching overvoltages, etc., thereby protecting the high-voltage electrical equipment from overvoltage damage.
The surge arrester is a composite-jacketed metal oxide surge arrester, which has advantages such as large current capacity, large protection margin, strong pollution resistance, small size, light weight, and convenient installation.
Note: Product parameters and related illustrations are for reference only. The actual delivered product shall prevail.

Technical Specifications

| Serial Number | project | unit | 9kV | 12kV | 15kV | 18kV | 21kV | 24kV | 27kV | 30kV | 36kV | |||
| 1 | Rated voltage | kV | 9 | 12 | 15 | 18 | twenty one | twenty four | 27 | 30 | 36 | |||
| 2 | Continuous operating voltage | kV | 7.65 | 10.2 | 12.7 | 15.3 | 17 | 19.5 | twenty two | 24.4 | 29 | |||
| 3 | Nominal discharge current | kA | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |||
| 4 | DC reference voltage (1mA) | kV | 13-14.1 | 17.2-18.9 | 21.5-23 | 24.5-27.5 | 28.7-31 | 33-36 | 37.2-40.5 | 43-46 | 51.6-55 | |||
| 5 | Residual pressure ≤ | Residual voltage under steep wave impulse current | 10kA | kVp | 29.3 | 39.1 | 48.9 | 56 | 66 | 76 | 85 | 95.7 | 114 | |
| Residual voltage under lightning impulse current | 10kA | 25.5 | 34 | 42.5 | 52 | 58 | 67 | 74 | 85 | 102 | ||||
| Residual voltage under operating inrush current | 500A | 21.4 | 29 | 36.9 | 43.5 | 49 | 51.7 | 58 | 64.5 | 76.9 | ||||
| 6 | 2ms square wave inrush current | A | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | 400 | |||
| 7 | 4/10 High Current Impulse Withstand Current | kA | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |||
| 8 | outer insulation withstand strength | Lightning impulse withstand voltage | kV | 47 | 63 | 78 | 94 | 110 | 125 | 141 | 156 | 188 | ||
| Short-time AC moisture withstand voltage | kV | twenty four | 32 | 39 | 47 | 55 | 63 | 71 | 78 | 94 | ||||
| 9 | Partial discharge ≤ | pC | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |||
| 10 | creepage distance | mm | 371 | 476 | 628 | 628 | 742 | 905 | 1019 | 1120 | 1265 | |||
| 11 | Surge arrester size | Insulator height L | mm | 124 | 135 | 194 | 194 | 214 | 284 | 304 | 316 | 377 | ||
| Umbrella diameter D/d | mm | Φ124/Φ94 | Φ124/Φ94 | Φ124/Φ94 | Φ124/Φ94 | Φ124/Φ94 | Φ124/Φ94 | Φ124/Φ94 | Φ124/Φ94 | Φ124/Φ94 | ||||
| Number of umbrellas | indivual | 5 | 7 | 9 | 9 | 11 | 13 | 15 | 17 | 19 | ||||
| 12 | resistor diameter | mm | Φ44 | Φ44 | Φ44 | Φ44 | Φ44 | Φ44 | Φ44 | Φ44 | Φ44 | |||