MNS low-voltage switchgear is a core piece of equipment in modern low-voltage power distribution systems, integrating power conversion, distribution, control, protection, and monitoring. It supports prefabrication and assembly, and units can be removed for line maintenance. The cabinet protection rating reaches IP30~IP40. With a rated voltage ≤690V and current up to 6300A, it features power distribution, fault protection, and intelligent monitoring functions, and is widely used in industrial, commercial buildings, infrastructure, and new energy fields, adaptable to various installation scenarios.

Share the model, quantity, drawing, destination and project requirement for a focused response.

Features

• Standardized components ensure universal compatibility, significantly reducing spare parts inventory and replacement costs.
• Anti-arc design effectively suppresses the spread of fault arcs, enhancing operational safety.
• Convenient expansion; no modifications to the main cabinet are required, and functional units can be added as needed.
• Fully enclosed busbar compartment design isolates external interference, reducing the risk of fault propagation.
• Adaptable to harsh operating conditions, possessing excellent temperature resistance, moisture resistance, and electromagnetic interference resistance.
MNS Low-Voltage Switchgear with Arc-Resistant Design product detail and application view 1
MNS Low-Voltage Switchgear with Arc-Resistant Design product detail and application view 2
MNS Low-Voltage Switchgear with Arc-Resistant Design product detail and application view 3

Range of Application

Its applications cover multiple core scenarios: in the industrial sector, it includes intelligent manufacturing, ports and wharves, and grain and oil processing; in commercial and public buildings, it covers places with extremely high requirements for power supply stability, such as hospitals, office buildings, and convention centers; in infrastructure, it can be adapted to urban rail transit, municipal water and power supply, and highway service areas; in the new energy sector, it is suitable for centralized photovoltaic power stations, distributed energy storage systems, and electric vehicle charging stations; in addition, it can also be used in special scenarios such as data center UPS power distribution and military-related classified locations.​​

Operating conditions

● Ambient Temperature: -5°C to +40°C, with a 24-hour average ≤+35°C.
● Atmospheric Conditions: Clean air with relative humidity ≤50% at +40°C. Higher humidity is permitted at lower temperatures (e.g., 90% at +20°C), but temperature variations may occasionally cause condensation.
● Altitude: ≤2000m.
● Transport & Storage Temperature: -25°C to +55°C, with short-term (≤24h) peaks up to +70°C. The equipment shall sustain no irrecoverable damage at these limits and shall operate normally under standard conditions.
Note: For applications exceeding the above conditions, please consult our company for customization.

Technical specifications

Items

Unit

Data

Rated operating voltage (Ue)(V) V

400/660

Rated insulation voltage (Ui)(V) V

660/1000

Rated frequency (Hz) Hz

50(60)

Horizontal busbar Rated current A

≤ 5000A

Rated short-time withstand current (Icw)(kA) kA

50,65,80 (Effective value for 1s)

Rated peak withstand current (Ipk)(kA) kA

105,140-176 (Maximum value for 0.1s)

Vertical busbar Rated maximum operating current A

≤ 1000A

Rated short-time withstand current kA

50kA

Rated peak withstand current kA

105kA

Overvoltage category V

IV, III

Pollution degree —

3

Protection level —

IP30/IP40(Special Instructions)

Note: The above data is subject to change due to technical improvement.

Product Features

  • Reference photos show a cabinet; the ordered internal arrangement must follow an approved drawing.
  • Specify incoming and outgoing circuits, busbar, protective devices and cable entries for quotation.
  • Confirm fault containment, rated currents, withstand levels and enclosure protection from configuration-specific test records.

Product Details & Applications

Use the photos to identify the cabinet format. They do not verify the devices, busbar layout or protection of the unit supplied for a particular order.

MNS Low-Voltage Switchgear with Arc-Resistant Design product detail and application view 1
MNS Low-Voltage Switchgear with Arc-Resistant Design product detail and application view 2
MNS Low-Voltage Switchgear with Arc-Resistant Design product detail and application view 3

Operating Conditions

Confirm ambient temperature, humidity, altitude, installation and storage requirements for the selected assembly against approved documents.

Technical Specifications

Request the technical schedule for the selected configuration, including rated voltage and current, busbar withstand, enclosure protection and applicable tests.

Additional Product Information

MNS low-voltage switchgear cabinet for project-specific configuration. Confirm circuit arrangement, ratings and test documentation before selection.

Inquiry Now

Send the model, drawing, BOM or project specification. Our team will respond around the actual selection points.

Open Full Enquiry Page

Search SUNENG

Find products, solutions, project references and articles.