Buzz | Project Solutions Engineer+86 131 8458 2748
Bella | Application Engineer+86 136 9956 4381sales@sunengelec.com
EN
Start an Enquiry
Low Voltage Switchgear

GCS Low Voltage Draw-Out Switchgear

Product Overview

The GCS device is applicable to power distribution systems in industries such as power plants, petroleum, chemical, metallurgy, textiles, and high-rise buildings. In highly automated venues like large power plants and petrochemical systems requiring computer interfacing, it serves as a low-voltage switchgear assembly for power distribution, motor centralized control, and reactive power compensation in three-phase AC systems with 50 (60) Hz frequency, rated working voltage of 380V (400V)/(660V), and rated current up to 4000A.

Share the model, quantity, drawing, destination and project requirement for a focused response.

Product Features

  • The frame is constructed with 8MF open-section steel, featuring Ф9.2mm mounting holes on the main structure with modular pitches of E=20mm and 100mm, enabling flexible and convenient assembly.
  • The functional compartments of the switchgear are fully isolated, including the functional unit compartment, busbar compartment, and cable compartment, each serving independent roles.
  • Horizontal busbars are arranged flat behind the cabinet to enhance their resistance to electrodynamic forces, a fundamental measure ensuring high short-circuit withstand capability in the main circuit.
  • The cable compartment is designed for easy top/bottom cable entry/exit.
  • Drawers are modular in height (160mm increments), with fixed width and depth dimensions. Drawers of the same functional unit are fully interchangeable, supporting rated currents up to 400A.
  • Drawer panels clearly indicate positions (On/Off/Test/Withdrawn) and are equipped with mechanical interlock devices. The drawer units combine withdrawable and fixed functions, allowing flexible configuration.
  • The cabinet’s protection rating is IP30/IP40 as standard, with custom options available upon request.

Product Details & Applications

GCS Low Voltage Draw-Out Switchgear product detail and application view 1
GCS Low Voltage Draw-Out Switchgear product detail and application view 2

Operating Conditions

  • Ambient Air Temperature: -5°C to +40°C, with a 24-hour average ≤+35°C. Derating operation is required when exceeding this.
  • Indoor Use: Altitude ≤2000m.
  • Relative Humidity: ≤50% at +40°C; higher humidity is permitted at lower temperatures (e.g., 90% at +20°C), with consideration for condensation risks due to temperature variations.
  • Installation Inclination: ≤5° from vertical, ensuring the panel lineup is level (complying with GBJ232-82).
  • Environmental Requirements: Free from severe vibration, shock, and corrosive conditions that may damage electrical components. Note: For applications exceeding the above conditions, please consult our company for customization.

Technical Specifications

ItemsData
Rated voltage of the main circuit(V)AC 380(400),(660)
Rated voltage of auxiliary circuit(V)AC 220,380(400), DC 110, 220
Rated frequency(Hz)50(60)
Rated insulation voltage(V)660(1000)
Rated current(A)Horizontal busbar≤4000
Rated current(A)Vertical busbar(MCC)1000
Rated short-time withstand current of busbar(kA,1s)50,80
Rated peak withstand current of busbar(kA/0.1s)105 ,176
Power frequency test voltage (V/1 min)Main circuit2500
Power frequency test voltage (V/1 min)Auxiliary circuit1760
BusbarThree phase four wireA.B.C.PE.N
BusbarThree phase five wireA.B.C.PE.N
Protection levelIP30, IP40

Inquiry Now

Send the model, drawing, BOM or project specification. Our team will respond around the actual selection points.

Open Full Enquiry Page

Search SUNENG

Find products, solutions, project references and articles.